F-2600 & F-2700 Vortex Flow Meter Manual 02/15 - 0808-7 / 19204 Page 31
7. Tighten the packing gland nuts to stop leakage around the stem. Do not torque over 20 ft-lbs.
8. Slide the stem clamp back into position. Torque stem clamp bolts to 15 ft-lbs. Replace the stem
clamp nuts and torque to 10-15 ft-lbs.
9. To separate the insertion tool from the ow meter, remove four socket head cap bolts securing
the upper and lower retractor brackets. Remove the insertion tool.
2.4.4 Installation of Meters with Packing Gland Connection (No Insertion Tool)*
Use the following formula to determine insertion depth for meters with a packing gland
connection (NPT and anged) without an insertion tool.
Insertion Length Formula
I = S - F - R - t
Where:
I = Insertion length.
S = Stem length - the distance from the center of the sensor
head to the base of the enclosure adapter (S = 29.47"
for standard probes; S = 41.47" for 12" extended probes).
F = Distance from the raised face of the ange or top of NPT
stem housing to the outside of the pipe wall.
R = Pipe inside diameter ÷ 2 for pipes 10" & smaller.
R = 5" for pipe diameters larger than 10".
t = Thickness of the pipe wall. (Measure the disk cutout
from the tapping procedure or check a piping
handbook for thickness.)
Figure 13. Insertion Calculation (Meters without Insertion Tool)
Example:
To install an insertion style ow meter with a standard probe (S = 29.47) into a 14"
schedule 40 pipe, the following measurements are taken:
F = 3"
R = 5"
t = 0.438"
The example insertion length is 21.03".
*All dimensions are in inches.