Onicon F-2600 Uživatelský manuál Strana 124

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 131
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 123
11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax (727) 442-5699 • [email protected]
F-2600 & F-2700 Vortex Flow Meter Manual 02/15 - 0808-7 / 19204 Page B-3
Fluid Calculations
Calculations for Steam T & P
When “Steam T & P” is selected in the “Real Gas” selection of the Fluid Menu,
the calculations are based on the equations below.
Density
The density of steam is calculated from the formula given by Keenan and Keys.
The given equation is for the volume of the steam.
v =
4.555.04 T
+ B
p
B = B
0
+ B
0
2
g
1
(τ) τ p + B
0
4
g
2
(τ)τ
3
p
3
- B
0
13
g
3
(τ)τ
12
p
12
B
0
- 1.89 - 2641.62 τ
1080870τ
2
g
1
(τ) = 82.546 τ 1.6246 10
5
τ
2
g
2
(τ) = 0.21828 - 1.2697 10
5
τ
2
g
3
(τ) = 3.635 10
-4
- 6.768 10
64
τ
24
Where tau is 1/ temperature in Kelvin.
The density can be found from 1/(v/ standard density of water).
Viscosity
The viscosity is based on an equation given by Keenan and Keys.
η (poise) =
1.501
10
-5
√T
1 + 446.8 / T
Where T is the temperature in Kelvin.
Zobrazit stránku 123

Komentáře k této Příručce

Žádné komentáře